GXZF350-IIIA/B
The type of the equipment:
|
GZF350-IIIB
|
Power supply mode:
|
220VAC
|
-48VDC
|
+27VDC
|
The frequency range of the test
|
DwPTS
|
361-365 MHz
|
UpPTS
|
351-355 MHz
|
Downlink test: the proximal distal end of input, output,361-365MHz
Test project
|
Index
|
Test results
|
The maximum output power
|
37±2dBm
|
37.1dBm
|
Gain (max)
|
75±3dB
|
76dB
|
Gain (factory value)
|
55±3dB
|
56dB
|
Gain adjustment range
|
≥30dB
|
40dB(Can gain the maximum 75dB adjusted to 35dB)
|
Gain adjusting step size
|
1dB
|
√
|
Bandwidth fluctuation
|
≤3dB(P-P)
|
2.3dB
|
out of band spurious emission test
|
9KHz~1GHz
|
≤-36dBm/100KHz
|
-42dBm
|
1GHz~12.75GHz
|
≤-30dBm/1MHz
|
-32dBm
|
Uplink test: the proximal distal end of input, output,351-355MHz
Test project
|
Index
|
Results (room temperature)
|
The maximum output power
|
≤0dBm
|
-0.5dBm
|
Gain (max)
|
75±3dB
|
76dB
|
Gain (factory value)
|
55±3dB
|
56dB
|
Gain adjustment range
|
≥30dB
|
40dB(Can gain the maximum 75dB adjusted to 35dB)
|
Gain adjusting step size
|
1dB
|
√
|
Bandwidth fluctuation
|
≤3dB(P-P)
|
2.1dB
|
out of band spurious emission test
|
9KHz~1GHz
|
≤-36dBm/100KHz
|
-42dBm
|
1GHz~12.75GHz
|
≤-30dBm/1MHz
|
-33dBm
|